Multi Gas / Gas Chromatographs
Dust / Opacity
Oil in water
Water in oil
Moisture
Sulfur
H2S / O2

Petroleum property analyzer

  • P950 Viscosity Index

    The updated design combines the traditional, reliable oil bath viscosity with key systems control upgrades. With the end user in mind, attention to design detail allows for ease of maintenance previously thought unattainable by conventional systems.

  • P900 Viscosity

    This updated classical design, combines traditional oil bath viscosity reliability with upgrades on systems control. Attention to design detail with the end user in mind allows for an ease of maintenance before thought unattainable by classical systems.

  • P840LT No flow pour point

    This small, compact and robust Peltier cooling system allows captured samples to be cooled to -60°C with external plant water coolant. The high pressure sample cell optics allow sample extraction and return to process and pressure conditions thereby eliminating the need for atmospheric recovery.

  • P820LT Cloud point

    This small, compact and robust Peltier cooling system allows captured samples to be cooled to -60°C with external plant water coolant. The high pressure sample cell optics allow sample extraction and return to process and pressure conditions thereby eliminating the need for atmospheric recovery.

  • P800LT Freeze point

    A self-contained cyrogenic cooling compressor out performs traditional Peltier Models reaching colder temperatures and eliminating the need for an expensive external cooling system. This small cooling system allows captured samples to be cooled to -125°C. The high pressure sample cell optics allow sample extraction and return to process and pressure conditions, thereby eliminating the need for atmospheric recovery.

  • P700 Reid vapor pressure

    Using a simply constructed, yet rugged, measurement chamber and sample delivery method, operational cost savings have been realized without complicating the analytical system. The Reid Bapor Pressure Analyzer demonstrates the optimization of the fluidics paths by employing components and materials that allow for a rapid measurement cycle without limiting accuracy, [...]

  • P600 Salt in crude

    In certain areas of the world, crude oils with high level of salts exist. This crude oil must still be transported and refined and the high levels of salt pose problems if left untreated. De-Salting technology is well established but to be utilized effectively the need for quick and accurate measurements of the level of salt concentration is necessary. The immediate response of an on-line analyzer allows the operator to use De-Salters as efficiently as possible.

  • P500 Flash Point Analyzer

    The Flash Point of mid-distillate products is one of the properties that must be maintained and controlled in order to produce and sell products to the market. The ORB P-500 is a state-of-the-art analyzer that implements the newest of electronics and detection principles for a low cost means of monitoring the Flash Point of a product during the refining process.